Cable Tray Loading Calculation Software

Below is the data for quick tray wire mesh cable tray fill table at 50 fills.
Cable tray loading calculation software. Cable tray pdms catalogs and specifications eaton teamed with aveva and intergraph content experts to develop b line series cable tray catalogs and specifications. Wire basket cable tray fill calculator cable tray sizing calculator. The electrical design engineer must use only spu approved electrical analysis software. This is the total weight of cables in the tray.
Skm power tools for windows ptw software. This table for cable tray sizes is provided by hoffman enclosures inc. Calculate cable tray width calculate cable tray area calculate cable tray length calculate cable tray weight calculate remaining width of cable tray calculate remaining area of cable tray free download. To maintain the load deflection figures stated in the tables the couplers should not be located in end spans or over support locations.
Cablofil wire mesh tray loading. Not required outside diameter cable qty cable size weight lbs ft total cable weight. 2 x 2 74. Cables of 0 21 o d.
On tue dec 2 2014 at 7 52 pm electrical notes articles wrote. The mechanical performance of all products and accessories is tested to the stringent requirements of the international standard iec 61537 and nema ve 1 csa 22 2. Lbs ft inside tray depth. The results should be validated with a hand calculation or order of magnitude estimate.
Some spu approved software tools are. Generally cable tray sizing is correct when it appears 50 full of cable or wire or when it contains a 50 fill of cables or wire. The cable tray sizing equals the width times the loading depth. The load ratings of the hardware that supports the quick tray wire mesh cable tray must also be considered load ratings for some commonly used supports are shown in the support maximum load table below.
Cable load foot 49 cables 20 lb 1000 ft. 9 to begin a new calculation return to the input screen and select the clear button. Which is subject to change at any time. Cable load working load the cable load or the working load is the total weight of the cables to be placed in the tray.
2 fill in all pertinent project information. Minimum allowable tray. Industrial design professionals using plant or smartplant 3d can click below for design content for b line cable tray. The length of tray additional supports will be required around bends and when the cable tray level changes.
Tray size of 0 1852 o d. The nema classes are based on cable loads of 50 75 and 100 per lineal foot. This will clear both the input and output pages. Cable pulling calculations generator capability motor starting.
The loading and deflection tables for unistrut cable tray assume that the couplers are located at the most onerous position within the span i e.